Figure 5-14: Loop Interface Module Wiring to Powered Sensor

{
BLK
FROM SIM
RED
GATEWAY
YEL
TRUNK
BLU

Figure 5-15: Loop Interface Module Wiring to Lacing/Foil and Non-powered Sensor

RF Gateway (472490)

The 5800ADT RF gateway provides additional RF points for the FOCUS 200 PLUS security system, up
to 72 points. The RF gateway is designed to be used in conjunction with a 5881H/5881EH/5882H RF
receiver only, and can support up to two receivers. It monitors individual 5800 series transmitters, and
only reports changes in their status to the control panel.
The Unit number for the RF gateway's identification with the control unit is fixed at Unit #7. Be sure
no other gateway is set to this value.
U L
The RF gateway and the RF receiver are not listed for UL Commercial Burglary applications.
472425 LOOP
INTERFACE MODULE
TB2
{
BLK
1
RED
2
YEL
3
BLU
4
472425 LOOP
INTERFACE MODULE
TB2
1
2
3
4
TB1
1
2
3
4
5
6
JUMPER
3K EOL
RESISTOR
TB1
LOW SIDE FEED
1
HIGH SIDE FEED
2
LOW SIDE RETURN
3
HIGH SIDE RETURN
4
5
6
Section 5 - Gateways
SENSOR
12V @ 80mA (max.)
+
TA
NO
C
NC
LACING / FOIL
BLK
RED
YEL
BLU
CONTACT
NO
C
NC
5-23