ADT FOCUS 200 PLUS Installation And Setup Manual page 95

Commercial fire and burglary security system with scheduling
Hide thumbs Also See for FOCUS 200 PLUS:
Table of Contents

Advertisement

Installing and Wiring the Electric Door Strike and Card/Key Reader (or Keylok)
ACIU Terminal
TB2-1 (-) (4)
TB2-2 (+)
TB2-3 (data "0")
TB2-4 (data "1")
TB2-5 (LED "A")
TB2-6 (LED "B")
NOT USED
TB3-1 Strike (-)
TB3-2 Strike (+)
(1) To extend reach of card/key readers for connection to ACIU, use manufacturer's extension cable or use 494461 Cable as noted
below.
(2) For Marlok applications:
a.
For a Marlok KEYLOK (comes with 5V internal solenoid), connect red and yellow keylok wires to TB3-1 and TB3-2,
respectively, and remove Jumper E11 in order to supply 5V to solenoid.
b.
For Marlok KEYREADER (works with the 12V stand-alone strike):
1.
Connect (+) and (-) terminals of strike to TB3-2 and TB3-1, respectively.
2.
Insert a 330-ohm +/- 5%, 1-watt resistor in series with the yellow wire from Keyreader to TB3-2.
3.
Connect red wire from Keyreader directly to TB3-1.
4.
Insert Jumper E11 to supply 12V.
(3) Strike requires 12VDC (E11 = IN). If not using strike, connect a 3K resistor across TB3-1 and TB3-2.
(4) Connect TB2-1 to CWG so that wire from reader will be returned to CWG.
(5) Cut resistor R8 on the ACIU circuit board, if you are using Dorado 7401 or 7901 card readers. See Figure 10-4.
To install the electric door strike and card/key reader or Keylok, perform the following steps:
Step
Action
1
Install the electric door strike and the card/key reader or Keylok in accordance with the
manufacturer's instructions.
2
Run the wiring in accordance with manufacturer's instructions, making sure that all
wiring to the ACIU does not exceed 150' (see Figures 10-2 and 10-3).
Where vendor extension cables are not available for the connections, use 494461 (6466-10)
Cable for the extension.
3
Set the DIP switch settings for the card reader, as required.
4
If you are not using a strike or a Keylok, install a standard 3K EOL resistor across TB3-1
and TB3-2 on the ACIU to simulate the strike load for the strike supervisory circuit.
Wiring Connections Between ACIU and Readers/Strike
Reader and Strike Wire Connections (1)
Marlok
Marlok
Keylok (2)
Keyreader
(2)
Brown
Brown
Green
Green
Orange
Orange
Black
Black
Red (2a)
Red (2b) (3)
Strike (-)
Yellow (2a)
330-ohm
Yellow (2b) (3)
Strike (+)
Using 494461 (6466-10) Cable for Extension
1 BLK
2 RED
3 BLU
4 ORG
5 YEL
Section 10 – Access Control
Sensor
Dorado (5)
Engineering
(Epic)
Black
Black
Red
Red
Green
Green
White
White
Violet
Brown
Brown
Blue
Yellow
Orange
Yellow
Strike (-) (3)
Strike (-) (3)
Strike (+) (3)
Strike (+) (3)
6—BRN
7—RED/BLK = Violet
8—BLU/BLK = Green
9—YEL/BLK = White
10—ORG/BLK
Motorola
Indala
Black
Red
Green
White
Brown
Blue
Orange
Strike (-) (3)
Strike (+) (3)
10-9