Installation and Connection
• Plug in all connectors only in off-circuit condition !
• Observe correct phase sequence of the motor!
• Shielded motor line
PE
W
PTC-Connector*
PTC-Connector*
Brake +
Brake –
Motor
Power connector
B
C
A
D
4
1
3
2
3.3.5 Connection of the temperature monitoring
•
Terminals T1, T2
•
Tripping resistance 1.65...4 kOhm
•
Reset resistance 0.75...1.65 kOhm
•
Design in accordance with VDE 0660 Part 302
•
This function can be activated by the machine builder by software
•
Do not lay connecting cable together with control cable
•
Permissible in the motor cable only with double shielding
•
Connect relay K1 for fire prevention in regenerative operation (see 3.3.6)
Motor connector
U
V
)
)
Connector
PIN No.
1
4
3
2
A
B
C
D
K1
12
11
Cable
Name
Core No.
U
V
W
PE
green-yellow
Brake +
Brake –
PTC contact
PTC contact
Other
Motor-PTC
X1.B
gr/ye
PE
1
U
2
V
3
W
PA
PB
7
T1
8
T2
5
ext. brake supply unit
6
with own voltage supply
(optionally)
Apply shieldings over a large
contact surface of the mounting
plate
1
2
3
5
6
7
8
T1
T2
11