KEB COMBIVERT F5 SERVO Installation Manualline page 22

Hide thumbs Also See for COMBIVERT F5 SERVO:
Table of Contents

Advertisement

CP-Parameter
CP.35 Reaction to limit switch
This parameter determines the reaction of the drive to terminal X2A.14 (F) and/or
X2A.15 (R), which are programmed as limit switches. The reaction of the drive is shown
in the table below.
CP.35 Display Response
0
E.PRx Immediate disabling of modulation
1
A.PRx Quick stopping / disabling of modulation after reaching
2
A.PRx Quick stop / holding torque at speed 0
3
A.PRx Immediate disabling of modulation
4
A.PRx Quick stopping / disabling of modulation after reaching
5
A.PRx Quick stop / holding torque at speed 0
6
none
CP.36 Reaction to external fault
With the external error monitoring external units can take direct influence on the drive.
This parameter determines the response of the drive to a signal at terminal X2A.12 (I3)
according to following table.
CP.36 Display Response
0
E.EF
1
A.EF
2
A.EF
3
A.EF
4
A.EF
5
A.EF
6
none
22
speed 0
speed 0
No effect to the drive; fault is ignored !
Immediate disabling of modulation
Quick stopping / disabling of modulation after reaching
speed 0
Quick stop / holding torque at speed 0
Immediate disabling of modulation
Quick stopping / disabling of modulation after reaching
speed 0
Quick stop / holding torque at speed 0
No effect to the drive; fault is ignored !
Restart
Remove fault;
reset
Autoreset, if no
fault is present
inapplicable
Restart
Remove fault;
reset
Autoreset, if no
fault is present
inapplicable

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

A6.f5.s3a-342a

Table of Contents