IBM TS3100 Setup, Operator, And Service Manual page 334

Tape library
Table of Contents

Advertisement

Table 66. LTO Tape Drive Sense Data (continued)
Byte
7
12-13
Additional Sense Code (ASC) -
Additional Sense Code Qualifier (ASCQ) (Continued)
Byte 12 Byte 13
ASC
ASCQ
27
00 - Write Protect - A Write type operation has been requested on a cartridge which
28
00 - Not Ready to Ready Transition - A cartridge has been loaded successfully into
28
01 - Import or export element accessed
29
00 - Reset - The drive has powered on, received a reset signal or a bus device
29
04 - Device internal reset
2A
01 - Mode Parameters Changed - The Mode parameters for the drive have
2C
00 - Command sequence error
2C
0B - Not reserved - The OIR bit of the sequential access device page
2F
00 - Commands cleared by another initiator
30
00 - Incompatible Media Installed - A write type operation could not be
30
01 - Unknown Format - An operation could not be carried out because the cartridge
30
02 - Incompatible Format - An operation could not be completed because the
30
03 - Cleaning Cartridge Installed - An operation could not be carried out
30
05 - Cannot write medium, incompatible format
30
07 - Cleaning Failure - A cleaning operation was attempted, but could not
30
0C - Data Protect - WORM overwrite attempted. The drive rejected a write operation
30
0D - Medium Error - WORM integrity check. The drive rejected a Read or Write
31
00 - Media format corrupted - Data could not be read because the format on tape is
37
00 - Rounded parameter - A Mode Select command parameter has been
3A
00 - Media Not Present - A media access command has been received
3B
00 - Sequential Positioning Error - A command has failed and left the logical
3B
0C - Position past beginning of medium
3D
00 - Invalid bits in identify Message - An illegal Identify Message has been
3E
00 - Logical Unit has not Self-Configured - The drive has just powered on and
3F
01 - Code Download - The firmware in the drive has just been changed
3F
03 - Inquiry data has changed
3F
0E - Reported LUNs data has changed
3F
0F - Echo buffer overwritten
40
xx - Diagnostic failure - A diagnostic test has failed. The xx (ASCQ) is a
306
IBM TS3100 Tape Library and TS3200 Tape Library: Setup, Operator, and Service Guide Machine Type 3573
6
5
has been write protected
the drive and is now ready to be accessed
reset signal since the initiator last accessed it
been changed by an initiator other than the one issuing the command
is set and the I-T nexus attempting to communicate with the drive does not hold
a reservation.
executed because it is not supported on the cartridge type that is loaded.
in the drive is of a format not supported by the drive
Logical Format is not correct
because the cartridge in the drive is a cleaning cartridge
be completed for some reason
because it would have resulted in an overwrite. Overwrite is not allowed on
WORM media.
operation because the cartridge is a suspicious WORM cartridge.
not valid, but is a known format. A failure occurred attempting to write the FID
rounded because the drive can not store it with the accuracy of the command.
when there is no cartridge loaded
position at an unexpected location
received at the drive at the start of a command
has not completed its self test sequence and can not process commands
by a Write Buffer command
vendor specific code indicating the failing component.
Bit Address or Name
4
3
2
1
0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ts3200

Table of Contents