The library controller card contains a copy of the vital product data (VPD) for your library. The VPD
contains your current library configuration. A backup copy of this VPD is contained within the electronics
of the Library Enclosure. When the library controller card is replaced, the new replacement card contains
zeros (0s) in key VPD locations. Upon detection of these zeros, the library automatically attempts to write
VPD data to the new library controller card from the backup copy of the VPD contained in the library
enclosure. In rare occurrences, the new library controller card might contain valid (non-zero) VPD data
left over from being installed in another library. If this action occurs, the library, which is expecting to see
zeros in the VPD area, instead detects valid VPD data, and does not know which copy of the VPD is the
correct one. It detects a "VPD Mismatch" and displays on the Operator Control Panel a screen entitled
"VPD Selection", where you must determine which copy of VPD is written to the new library controller
card.
If the message "VPD Selection" is displayed at the Operator Control Panel, carefully highlight the "VPD
from Enclosure" option to copy that version of the VPD to the new library controller card. Then, continue
with the procedure.
Removal and Replacement
Procedure
1. Power OFF the library by pressing and holding the power button at the front of the library for 4
seconds.
2. Disconnect the power cord from the electrical source, then from the power supply or supplies at the
back of the library.
3. Loosen the two blue captive thumbscrews on the library controller card.
4. Grasp the two thumbscrews and pull the defective library controller card out of the library.
Figure 176. A library controller card that is removed from the library
5. Remove the packaging from the replacement library controller card.
6. Grasp the two thumbscrews and push the replacement library controller card into the library.
7. Tighten the two blue captive thumbscrews on the library controller card.
8. Connect the power cord to the power supply or supplies at the back of the library, then to the
electrical source.
9. Power ON the library with the power button on the front panel.