IBM TS3100 Setup, Operator, And Service Manual page 233

Tape library
Table of Contents

Advertisement

Table 52. Main Error Codes (continued)
Error Code Description
DC
I²C Bus Failure
DD
Warning Event! See Table 54 on page 211
DE
Warning Event! See Table 54 on page 211
DF
Warning Event! See Table 54 on page 211
E0
Incompatible magazine that is detected
E2
New hardware found. Library firmware upgrades required.
EB
Power supply health check failed because of a power supply
failure.
F0
Drive Over temperature Condition
The subcode indicates which drive is affected.
Example:
Subcode 02: drive #2
User Action
1. Retry the operation.
2. After several occurrences, refer to
"Contacting IBM technical
support" on page 219.
1. Remove magazine from library.
2. Insert magazine in library. If error
recurs, refer to "Contacting IBM
technical support" on page 219.
Upgrade library firmware to the
latest version.
Refer to "Isolating a power supply
problem" on page 194
1. Check the ambient temperature
conditions, and check all fans.
2. Refer to "Isolating drive sled
problems" on page 196.
Error codes