Table 54. Warning events (continued)
67
Medium error, incompatible medium for
write operation
6A
Medium error, no OBDR tape
70
Currently not used
71
Currently not used
72
Currently not used
73
SCSI: overlapped command attempt
74
SCSI: echo buffer overwritten
75
Download prevented due to
incompatible bar code reader hardware
77
Download prevented due to
incompatible LCM
78
Download prevented due to
incompatible Rob Code
79
Download prevented due to
incompatible drive version
80
Movement Retry.
81
Fan Alert.
82
Clean request from drive.
83
Media Attention.
84
Drive reported warning or critical tape
alert flag.
85
Network problem.
86
Not enough cleaning cartridges present
to autoclean.
87
Drive disabled because it is not
supported for use in this library.
88
Drive firmware unchanged after
upgrade.
89
Power Supply Fan operation warning.
8A
Power Supply failed.
8B
Power supply failed.
8C
Invalid Robotic Code.
8E
Cleaning tape nearly expired.
8F
I2C bus recovery.
92
VPD data have been restored from
EEPROM.
Replace incorrect cartridges.
Insert OBDR tape.
Refer to your host application documentation for problem
determination information.
Older firmware image doesn't support current bar code
reader hardware. No downgrade possible.
Older firmware image doesn't support current library
controller hardware. No downgrade possible.
Older firmware image doesn't support current robotics
controller hardware. No downgrade possible.
Use correct drive firmware image.
Check network connections, configuration, and settings.
Insert more cleaning cartridges to the empty reserved slots.
Check drive type and install only supported drives.
This is normal if the old and new drive firmware is the
same version.
Check the power supply status.
Check the power supply status and replace the failed power
supply.
Check the power supply status and replace the failed power
supply.
Install the latest version of library firmware.
Continue with cleaning cartridge until it is expired, then
replace the expired cleaning cartridge with a new cleaning
cartridge.
Run library System Test.
This is normal when the VPD is restored EEPROM.
213
Error codes