drive that is shown as 1 Figure 214.
Figure 214. Leader Block Assembly (LBA)
10. Continue rotating the loader motor worm gear ( 1 in Figure 213 on page 279) until the rotator stub
( 3 in Figure 213 on page 279) is positioned as shown. Notice that the rotator stub ( 3 in
Figure 213 on page 279) is nearly aligned with the cartridge loader tray guide bearing ( 2 in
Figure 213 on page 279).
11. Remove the cartridge from the cartridge loader tray.
12. Go to "Ending procedure" on page 283.

Half height drive: No apparent failure or damage to tape

About this task
Note: If the cartridge in the drive is an INPUT tape that contains ACTIVE or 'ONLY COPY' data (there is
no backup), eject commands that are issued at the host fail to unload the tape, and power-cycling the
drive fails to eject the cartridge, make no further attempts to unload this tape. Call Technical Support
and open a PMR if one is not already open, to initiate the process of sending the drive with the loaded
cartridge in for recovery.
Procedure
1. Set the drive on its left side with the head and tape path facing up.