Description
Byte
Bit
0
1
2
0
3
4
5...7
1
0
Bit SINGLE: If this bit is set to 1, a single measurement is output
Bit POS:
Bit SLEEP: If this bit is set to 1, the Standby mode is activated.
Bit M:
Bit D:
It is advisable to set only one bit in the request byte, as the BPS can only answer one request
at a time. If several bits are set, the function with the highest priority is executed.
Priority of the bits in the request byte:
• Priority 1:
• Priority 2:
• Priority 3:
• Priority 4:
• Priority 5:
Leuze electronic
Name
Function
D
Request
diagnostic information
M
Request
marker data
SLEEP
Activate
Standby mode
POS
Request
position information
SINGLE
Request
single measurement
None
XOR
XOR combination
(laser on – measurement – laser off).
The response telegram to the "SINGLE" request is sent after around 40 ms.
The "SINGLE" request cycle must be greater than 40 ms.
If this bit is set to 1, the position data is output.
The "POS" request cycle must be greater than 10 ms. If the no "POS" request
occurs within 10 ms, the laser is deactivated. A response telegram is sent to
a repeat "POS" request after approx. 30 ms.
The polygon wheel motor and the laser are switched off in Standby. Diagnosis
of the read system cannot be performed. When the device is reactivated, the
system start-up time is approx. 5 s.
If this bit is set to 1, the marker bar code content is output.
If this bit is set to 1, the diagnostic data is sent in response. An indicated error
is reset once all diagnostic data has been polled. This is indicated by the status
LED changing from red to green.
Diagnostic data request (D)
Marker data request (M)
Standby request (SLEEP)
Position data request (POS)
Request for one-time transmission of position data (SINGLE)
Protocols for position value output
Description
1 = Request diagnostic data
0 = Do not request diagnostic data
1 = Request marker data
0 = Do not request marker data
1 = Activate Standby mode.
0 = Positioning mode
1 = Request position data
0 = Do not request position data
1 = Request single measurement (laser on, measurement, laser off)
0 = Do not request single measurement
Without function, bit permanently set to 0
Exclusive OR combination of byte 0 with 00
BPS 8
h
85