Control - Leuze electronic BPS 8 Original Operating Instructions

Bar code positioning system
Table of Contents

Advertisement

8.5.1

Control

Figure 8.5: Control tab
Description:
The control manages the timing of the position calculation by starting and stopping the
decoding. Control is performed depending on certain events such as the switching input or
time functions. Using parameters, the events which influence the states are determined.
Parameters
Parameter
a
Start mode
b
Stop mode
c
Maximum
polling
interval
Leuze electronic
Description
The start mode determines by
which event the position mea-
surement is started.
The stop mode determines after
which event the position mea-
surement is stopped.
Time period after which the
scanning beam is switched off if
no polling takes place.
Configuration / device parameters
Value range
1: After initialization
2: Via command or
switching input
2: Time (Polling Interval)
3: Time with re-trigger-
ing function (polling
interval) via com-
mand or switching
input
4: Via command or switch-
ing input (the switching
input must be pro-
grammed for this pur-
pose)
0 ... 65,535
BPS 8
Default
Unit
CR
Switching
input
2
Switching
input
3
10,000
ms
h
h
72