9.5.3
BPS 8 SM 10x-10 response telegram
The response telegram consists of 6 bytes.
Response telegram structure
Byte no.
Designation
0
Status byte
1
Data byte 1
2
Data byte 2
3
Data byte 3
4
Data byte 4
5
XOR combination
Description
Byte
Bit
0
1
2
0
3
4
5
6
7
1...4
0...7
5
0...7
Position data
The position data are output in two's complement as a 32-bit signed integer value by
default in millimeters with a resolution of 1 mm (see chapter 8.5.2 "Position detection")
The P00 data bit corresponds to the LSB, the P31 data bit corresponds to the MSB.
Leuze electronic
Bit 7
0
P31
P23
P15
P07
Bitwise exclusive OR combination of bytes 0 to 4
Name
Function
ERR
Internal error
OUT
Tape error
DIB
Diagnostic data exist
–
None
–
None
Q0
Reading quality Q1Q0
Q1
–
None
Data,
Data
P31 ... P00
XOR
XOR combination
Protocols for position value output
Bit 6
Bit 5
Bit 4
Q1
Q0
0
P30
P29
P28
P22
P21
P20
P14
P13
P12
P06
P05
P04
Description
1 = An internal error has occurred
0 = No error exists
1 = No bar code decodable
0 = Bar code decodable
1 = Diagnostic data are present in the memory
0 = No diagnostic data exists
Without function, bit permanently set to zero
Without function, bit permanently set to zero
00 = Reading quality > 75%
01 = Reading quality 75% ... 50%
10 = Reading quality 50% ... 25%
11 = Reading quality < 25%
Without function, bit permanently set to zero
Depending on the request, the data are transferred here; either posi-
tion data, diagnostic data, marker data or SLEEP response.
Bitwise exclusive OR combination of bytes 0 to 4
BPS 8
Bit 3
Bit 2
Bit 1
0
DIB
OUT
P27
P26
P25
P19
P18
P17
P11
P10
P09
P03
P02
P01
Bit 0
ERR
P24
P16
P08
P00
111