Bps 8 Sm 10X-02 Response Telegram - Leuze electronic BPS 8 Original Operating Instructions

Bar code positioning system
Table of Contents

Advertisement

9.2.3

BPS 8 SM 10x-02 response telegram

The response telegram consists of 8 bytes.
Response telegram structure
Byte no.
Designation
0
Status byte
1
Data byte 1
2
Data byte 2
3
Data byte 3
4
XOR combination
5
Repetition of data byte 1
6
Repetition of data byte 2
7
Repetition of data byte 3
Description
Byte
Bit
0
1
2
3
0
4
5
6
7
8
1...3
0...8
4
0...8
5...7
0...8
Leuze electronic
Bit 8
0
0
0
0
Bitwise exclusive OR combination of bytes 0 to 3
0
0
0
Name
Function
ERR
Internal error
OUT
Tape error
QT0
Reading quality Q1Q0
QT1
A0
Address A1A0 in
RS 485 network
A1
M
Marker data exists
D
Diagnostic data exist
None
Data,
Data
P23 ... P00
XOR
XOR combination
Data,
Data resend
P23 ... P00
Protocols for position value output
Bit 7
Bit 6
Bit 5
D
M
A1
P23
P22
P21
P15
P14
P13
P07
P06
P05
P23
P22
P21
P15
P14
P13
P07
P06
P05
Description
1 = An internal error has occurred
0 = No error exists
1 = No bar code decodable
0 = Bar code decodable
00 = Reading quality > 75%
01 = Reading quality 75% ... 50%
10 = Reading quality 50% ... 25%
11 = Reading quality < 25%
00 = Address 0
01 = Address 1
10 = Address 2
11 = Address 3
1 = Marker data are in the memory
0 = No marker data in the memory
1 = Diagnostic data are present in the memory
0 = No diagnostic data exists
Without function, bit permanently set to zero
Depending on the request, the data is transferred here; either posi-
tion data, diagnostic data or marker data.
Bitwise exclusive OR combination of bytes 0 to 3
Depending on the request, the data is transferred here; either posi-
tion data, diagnostic data or marker data.
BPS 8
Bit 4
Bit 3
Bit 2
Bit 1
A0
QT1
QT0
OUT
P20
P19
P18
P17
P12
P11
P10
P09
P04
P03
P02
P01
P20
P19
P18
P17
P12
P11
P10
P09
P04
P03
P02
P01
Bit 0
ERR
P16
P08
P00
P16
P08
P00
93