Parameters
Parameter
a
Digital
I/O mode
b
Inversion
c
Mode
d
Debounce
time in [ms]
e
Start-up
delay in
[ms]
f
Pulse dura-
tion in [ms]
g
Switch-off
delay in
[ms]
h
Function
The switching input function Pos. measurement start/stop in the Function parameter
means:
• High level at the switching input starts the position measurement.
• Low level at the switching input stops the position measurement.
Leuze electronic
Description
Defines whether the switching
input and output are activated
via the MA 8-01/MA 8-02 or
whether only the switching input
or only the switching output is
activated.
The parameter defines the logic
of the applied signal. In case of
an inversion, an external HIGH
level is interpreted as an inter-
nal LOW level.
This parameter controls the
release of the switching input.
This parameter defines a
debounce time which is imple-
mented via software.
The parameter influences the
timing during switch-on.
The parameter defines a mini-
mum time period before the sig-
nal is reset.
The parameter defines a time
delay for the signal during
switch-off.
The parameter specifies the
function which is to be activated
or deactivated by a status
change at the switching input.
Configuration / device parameters
Value range
0: Not released
1: BPS 8 with MA 8-01/
MA 8-02 (switching
input + switching
output)
2: Switching input
3: Switching output
0: No (active high)
1: Yes (active low)
0: Off
1: On
0 ... 255
0 ... 65535
0 ... 65535
0 ... 65535
0: No function
1: Teach preset
2: Start/stop position
measurement
3: Stop position mea-
surement
BPS 8
Default
Unit
CR
1
0
1
5
ms
0
ms
0
ms
0
ms
Position
detection
2
Control
Control
e
a
b