7.4.3
BCL/BPS socket – connecting the BPS 8 to the MA 8-01/MA 8-02
RXD
SWIN/SWOUT
GND
M12 socket
(A-coded)
Figure 7.10: MA 8-01/MA 8-02 – Pin assignment BCL/BPS socket
CAUTION
Degree of protection IP 67!
Degree of protection IP 67 is achieved only if the connectors and caps are screwed into
place!
The BPS 8 is connected to the MA 8-01/MA 8-02 via the KDS S-M12-5A-M12-5x-P1-xxx
interconnection cable. The voltage supply is connected via the PWR IN HOST/RS485
socket.
CAUTION
Connect functional earth!
 Ensure that the functional earth (FE) is connected correctly.
Fault-free operation is only guaranteed if the functional earth is connected properly.
Leuze electronic
BCL/BPS (5-pin socket, A-coded)
Pin
VIN
4
1
1
5
2
3
2
TXD
3
BCL / BPS
4
5
Thread
Name
Supply voltage for BPS 8
VIN
aprox. +5.2VDC
TXD
RS 232 transmission line
GND
Supply voltage: 0VDC
RXD
RS 232 receiving line
SWIN/
Programmable switching input/output of the
SWOUT
BPS 8
FE
Functional earth (housing)
BPS 8
Electrical connection
Comment
59