Bit ON:
Bit OFF:
Bit DIAG:
It is advisable to set only one bit in the request byte, as the BPS can only answer one request
at a time. If several bits are set, the function with the highest priority is executed.
Priority of the bits in the request byte:
• Priority 1:
• Priority 2:
• Priority 3:
Leuze electronic
If this bit is set to 1, measurement operation and the cyclical output of position
data are activated. The position data are transmitted cyclically from the BPS.
If this bit is set to 1, measurement operation is deactivated and the cyclical
output of data is stopped. If measurement operation and the cyclical output of
position data are re-activated, the boot time is 5 s.
If this bit is set to 1, diagnostic data can be requested. An indicated error is
reset once all diagnostic data has been polled. This is indicated by the status
LED changing from red to green.
Diagnostic data request (DIAG)
Deactivate cyclical output of position data and measurement operation
(OFF)
Activate cyclical output of position data and measurement operation
(ON)
Protocols for position value output