9.1.3

BPS 8 SM 10x-01 / BPS 8 SM 10x-05 response telegram

The response telegram consists of 6 bytes.
Response telegram structure
Byte no.
Designation
0
Status byte
1
Data byte 1
2
Data byte 2
3
Data byte 3
4
Data byte 4
5
XOR combination
Description
Byte
Bit
0
1
2
3
0
4
5
6
7
1...4
0...7
5
0...7
Position data
The position data are output in two's complement as a 32-bit signed integer value by
default in millimeters with a resolution of 1 mm (see chapter 8.5.2 "Position detection")
The P00 data bit corresponds to the LSB, the P31 data bit corresponds to the MSB.
Leuze electronic
Bit 7
0
P31
P23
P15
P07
Bitwise exclusive OR combination of bytes 0 to 4
Name
Function
ERR
Internal error
OUT
Tape error
D
Diagnostic data exist
MM
Marker bar code present
SLEEP
Standby state
Q0
Reading quality Q1Q0
Q1
None
Data,
Data
P31 ... P00
XOR
XOR combination
Protocols for position value output
Bit 6
Bit 5
Bit 4
Q1
Q0
SLEEP
P30
P29
P28
P22
P21
P20
P14
P13
P12
P06
P05
P04
Description
1 = An internal error has occurred
0 = No error exists
1 = No bar code decodable
0 = Bar code decodable
1 = Diagnostic data are present in the memory
0 = No diagnostic data exists
1 = The content of a marker bar code is in the memory
0 = No content of a marker bar code in the memory
1 = Device is in Standby mode
(see request telegram)
0 = Device is in positioning mode
00 = Reading quality > 75%
01 = Reading quality 75% ... 50%
10 = Reading quality 50% ... 25%
11 = Reading quality < 25%
Without function, bit permanently set to zero
Depending on the request, the data are transferred here; either posi-
tion data, diagnostic data, marker data or SLEEP response.
Bitwise exclusive OR combination of bytes 0 to 4
BPS 8
Bit 3
Bit 2
Bit 1
MM
D
OUT
P27
P26
P25
P19
P18
P17
P11
P10
P09
P03
P02
P01
Bit 0
ERR
P24
P16
P08
P00