8.5.3

Communication

Figure 8.8: Communication tab
Parameters
Parameter
a
Baud rate
b
Data
mode
c
Protocol
d
Address
The 5 different binary protocols are described in a separate chapter (see chapter 9 "Proto-
cols for position value output").
Leuze electronic
Description
4:
5:
6:
7:
Setting the baud
8:
rate.
9:
10: 57600
11: 62500
12: 115200
13: 187500
1:
2:
3:
4:
5:
6:
Setting of the data
7:
mode.
8:
9:
10: 8 data bits, odd parity, 1 stop bit
11: 8 data bits, odd parity, 2 stop bits
12: 8 data bits, no parity, 1 stop bit + WakeUp
13: 9 data bits, no parity, 1 stop bit
17: Binary protocol 2
18: Binary protocol 3
Setting the proto-
19: Binary protocol 1
col type.
20: Binary protocol 4
23: Binary protocol 6
Sets the partici-
0: Address 0
pant address for
1: Address 1
the RS 485 net-
2: Address 2
work.
3: Address 3
Configuration / device parameters
Value range
1200
2400
4800
9600
19200
38400
7 data bits, no parity, 2 stop bits
7 data bits, even parity, 1 stop bit
7 data bits, even parity, 2 stop bits
7 data bits, odd parity, 1 stop bit
7 data bits, odd parity, 2 stop bits
8 data bits, no parity, 1 stop bit
8 data bits, no parity, 2 stop bits
8 data bits, even parity, 1 stop bit
8 data bits, even parity, 2 stop bits
bit
BPS 8
Default
Unit
CR
10
Baud
6
19
0
78