4.2

MA 8-01 / MA 8-02 connection unit

The modular connection unit is an optional accessory when connecting a BPS 8 to an
RS 485 interface. The RS 485 interface, the switching input and the switching output are all
connected to the MA 8-01/MA 8-02. It also supplies voltage to the BPS 8. The MA 8-01/
MA 8-02 connection unit offers the following advantages over the installation of the BPS 8
as a stand-alone device:
• M12 socket for switching input and switching output
• M12 connector for RS 485 interface and voltage supply 24VDC
• M12 socket for connection of the BPS 8
C
A
M12 socket, 5-pin, A-coded
B
M12 connector, 5-pin, A-coded
C
FE connection
Figure 4.2: Dimensioned drawing and pin assignment of the MA 8-01/MA 8-02 connection
Leuze electronic
MA 8... / MA 2xxi connection units
BPS 8
A
B
all dimensions in mm
18