Leuze electronic BPS 8 Original Operating Instructions page 26

Bar code positioning system
Table of Contents

Advertisement

The control bar codes are simply affixed over the existing bar code tape.
NOTE
Grid dimension of control/marker bar code!
The control/marker bar code must match the selected grid of the bar code tape used. If a
30 mm grid is used (default), then the control/marker bar code must also be inserted in the
30 mm grid. With a 40 mm grid, a 40 mm control/marker bar code is used.
Keep the gap between the BCBs that are switched between as small as possible.
A
BCB8
B
BCB8
A Control bar code perfectly affixed on the bar code tape
B Control bar code at small gap between two bar code tapes
Figure 5.3: Correct positioning of the control bar code
NOTE
Gaps in bar code tape!
 Avoid polished and high-gloss surfaces.
 Keep the gaps between the two bar code tapes and the control bar code as small as
possible.
Leuze electronic
BCB8
BCB8
BCB8
BCB8
BPS 8
Bar code tape
BCB8
BCB8
BCB8
24