BCB mounting in vertical curves
NOTE
Limited absolute measurement accuracy and reproducibility!
 BCB mounting in curves decreases the absolute measurement accuracy of the BPS,
since the distance between two bar codes is no longer exactly 30 mm.
 In areas where the BCB is fanned out around curves, limitations of the reproducibility
must be expected.
 Only partially cut the BCB at the cut mark.
 Affix the BCB along the curve like a fan ((see figure 6.5)).
 Ensure that the BCB is affixed without mechanical tension.
NOTE
No glossy gaps in the bar code tape!
 Ensure that there are matt, bright surfaces behind the fanning in the BCB curves.
Polished, reflective, and high-gloss surfaces in the scanning beam may impair the
measurement quality of the BPS.
BCB8
Figure 6.5: Preparing the bar code tape for use in vertical curves