Service Operating Mode; Activate Service Interface; Connecting The Service Interface - Leuze electronic BPS 8 Original Operating Instructions

Bar code positioning system
Table of Contents

Advertisement

8.3

Service operating mode

Setting the required parameters is carried out in the Service operating mode. The operating
mode Service provides the following defined operating parameters on the external RS232
interface, no matter how the BPS 8 is configured for standard operation:
• Transmission rate: 9.6 kBit/s
• No parity
• 8 data bits
• 1 stop bit
• Prefix: STX
• Postfix: CR, LF
8.3.1

Activate service interface

The service interface may be activated as follows:
• Via a "v" command during power-up (initialization phase).
• Via the SRV control bar code (see accompanying package insert) in front of the read-
ing window during power-up (initialization phase)
Figure 8.3: SRV control bar code
8.3.2

Connecting the service interface

You can connect a PC or a terminal to the BPS 8 via the serial interface and configure the
BPS 8 through this connection. For this, you need a crossed RS 232 interconnection cable
(null modem cable) that provides the connections RxD, TxD and GND. A hardware hand-
shake via RTS, CTS is not supported at the service interface.