9.5
Binary protocol 6 – BPS 8 SM 10x-10
With the BPS Configuration Tool, the user can individually adapt the binary protocols 1
and 6 to the specific requirements of the application. The binary protocols 2, 3 and 4, on the
other hand, have a fixed structure and cannot be modified.
9.5.1

Data format

Data format
Baud rate
Number of data bits
Number of start bits
Number of stop bits
Parity
Addressing
Operating mode
Handshake
Table 9.5:
9.5.2

Request telegram to the BPS 8 SM 10x-10

The request telegram consists of two bytes.
Request telegram structure
Byte no.
Designation
0
Request byte
1
XOR combination
Description
Byte
Bit
0
1
2
0
3
4...7
1
0
Leuze electronic
BPS 8 SM 10x-10 data format
Bit 7
0
Exclusive OR combination of byte 0 with 00
(repetition of the request byte)
Name
Function
DIAG
Request
diagnostic information
None
OFF
Deactivate measurement
operation
ON
Activate measurement opera-
tion
None
XOR
XOR combination
Protocols for position value output
BPS 8 SM 10x-10
115.2 kBit/s
8
1
1
None
None
RS 232 full duplex
None
Bit 6
Bit 5
Bit 4
0
0
0
Description
1 = Request diagnostic data
0 = Do not request diagnostic data
Without function, bit permanently set to 0
1 = Deactivate measurement operation and cyclical measurement
value output
0 = No function
1 = Activate measurement operation and cyclical measurement
value output
0 = No function
Without function, bit permanently set to 0
Exclusive OR combination of byte 0 with 00
BPS 8
Bit 3
Bit 2
Bit 1
ON
OFF
0
h
h
Bit 0
DIAG