APPENDIX 5

The E9 NEXT unit can perform three sterilization cycles; the parameters of each cycle are summarised in the
table below:
Parameters
Temperature
Pressure
Length of sterilization phase
(plateau period)
Drying time (Auto)
Maximum load (solid/porous)
Sterilization phase
The cycle profile may vary from one software version to another.
Fractioned preliminary
vacuum
Sterilization phase
Drying

Description of programs

Cycle
B134
NEXT 18/24L
135.5°C
2.15 bar
4'
15'
4.5/1.5 kg –
6/2 kg
Sterilization phase
V1
P1
V2
P2
V3
P3
STS
STE
D1
D2
D3
DE
B134 PRION
NEXT 18/24L
NEXT 18/24L
135.5°C
2.15 bar
18'
15'
4.5/1.5 kg –
4.5/1.5 kg –
6/2 kg
Fractioned preliminary vacuum
1st vacuum
1st pressure rise
2nd vacuum
2nd pressure rise
3rd vacuum
3rd pressure rise
Start of sterilization period
End of sterilization period
Start of drying phase
End of swift drying phase
Start of common drying phase
End of common drying phase
69
Aquafilter
E9 NEXT
B134 RAPIDO
B121
/ B134 PRION
RAPIDO
NEXT 18/24L
121.5°C
135.5°C
1.15 bar
2.15 bar
20'
3.5' / 18
15'
5'
0.6/0.2 kg –
6/2 kg
0.6/0.2 kg