Adjustment Of The Closing Mechanism - Euronda E9 Next 18L Instruction Manual

Table of Contents

Advertisement

9.2.2 Adjustment of the closing mechanism

CAUTION:
cold.
The closing mechanism of the unit occasionally requires adjusting due to normal settling of mechanical parts
and wear on the seal gasket. This is particularly important as a poor seal may prevent the pressure from
increasing to the level set for the selected program and therefore jeopardise the result of the cycle. Proceed
as follows:
1. Open the door. Always work with the unit cold.
2. Fit the supplied adjustment lever (Fig. 9.2.2-1) into the slot under the door (Fig. 9.2.2-2).
Fig. 9.2.2-1
3. Look through the slot of the door hook to make sure the lever has engaged the adjustment pin. (Fig.
9.2.2-3).
Fig. 9.2.2-3
4. Turn the adjustment pin anticlockwise, looking at the door gasket, by 1/4 of a turn (to close) (Fig. 9.2.2-4).
5. Check that the door closes properly. If the handle is too hard to close, turn a little in the opposite direction
(clockwise).
6. Carry out a test cycle to check it is correctly adjusted.
HIGH TEMPERATURE. Only perform this operation when the machine is
Fig. 9.2.2-2
Fig. 9.2.2-4
61