Air hose connection

This step in the installation is critical. If the connections are not secured properly, products
of combustion could disperse into the room being heated.
WARNING
The Linear comes with one end of the flexible air hose already connected to the Linear air inlet.
Attach the other end of the air intake hose to the connection on the flue, either the ASPDFK or the
EVOKIT03.
Connect the flue into the Linear combustion fan exhaust, and secure in place (two screws) with the
flue lock bracket (supplied in the plastic bag with the remote control).
Secure the air intake hose on the flue with the cable tie (supplied in the plastic bag with the remote
control), and ensure the rubber cap is in place on the unused air intake.
Rubber cap placed on
the unused air intake
Flue lock bracket
holding the EVOKIT03
in place.
This end of the flexible
air hose comes already
connected to the air
inlet.
42 | Linear installation guide 13563-B 02-19
Air intake hose
connected to the
EVOKIT03 and secured
with a cable tie
EVOKIT03 connected
into the Linear
combustion fan
exhaust.