GAS CONNECTION

RUN GAS SUPPLY
For pipe sizing, refer to your local gas installation codes.
Copper supply should be run leaving a flared connection
at the position shown.
PURGE SUPPLY OF AIR AND SWARF.
All foreign materials such as filings must be purged from
the gas supply, as they may cause the gas valve to
malfunction.
SLIDE HEATER INTO FIREPLACE
Slide the heater carefully into position.
A spring-loaded debris diverter plate is fitted to
prevent the entry of foreign objects for a masonry
chimney installation.
The plate will fold down as the heater slides through the
fireplace opening. Once the heater is in place the plate
will resume its normal position.
IMPORTANT: Make sure that the debris diverter plate
is not restricted and returns to its normal position
when the heater is installed.
If the fire has to be removed, the plate will pivot
downwards to allow the heater to slide clear.
When a flue liner is used, the debris diverter plate
must be unscrewed and removed.
Feed the copper tube through the supply access
opening.
Connect and tighten union.
Secure heater to fireplace. There are pre-drilled holes
in the heater flanges.
Drill additional holes if the existing ones are not in
suitable positions.
On completion of work, check for gas leaks.
8