NOTE: Incoming water supplies that do not meet the
influent water characteristics requirements will
require the addition of pretreatment equipment prior
to the Conserv HE-3 RO System.
SELECTING A MOUNTING LOCATION
Locate the system in an area that is convenient to the inlet
water supply and drain facilities, with access for routing
the blended water tubing/piping to the equipment. Install
in a dry location, away from all forms of corrosive and/or
flammable materials. Consider ease of access for servicing
when selecting a location. If the Conserv HE-3 RO System
is replacing an existing Everpure
Efficiency RO System the mounting system may be reused.
The Conserv HE-3 is designed to mount using the MRS-600
HE-II wall mount brackets. The Conserv HE-3 may also be
mounted using a new design wall mount hinge system (sold
separately).
If the Conserv HE-3 RO System is wall mounted on hinges be
certain the unit has clearance to swing out for maintenance.
Evaluate the mounting surface for its ability to properly
support the weight of the processor when in operation
[approximately 90 lbs (40.8 kgs)].
14.4"
(36.5 cm)
23.5"
(59.7 cm)
Figure 1 Left Swing Clearance
18.4"
(46.7 cm)
14.4"
(36.5 cm)
Figure 2 Right Swing Clearance
EVERPURE
CONSERV
HE-3 RO SYSTEM INSTALLATION AND OPERATION GUIDE
®
®
MRS-600HE-II High
®
18.4"
(46.7 cm)
14.4"
(36.5 cm)
14.4"
(36.5 cm)
23.5"
(59.7 cm)
DIMENSIONS
18.4"
(46.7 cm)
29.0"
(73.6 cm)
Figure 3 Conserv HE-3 RO System Dimensions
13.4"
(34.0 cm)
27.9"
(70.8 cm)
Figure 4 Conserv HE-3 RO System Storage Tank Dimensions

PRE-INSTALLATION CHECKLIST

1. Can the unit be mounted within a reasonable distance of
the water supply, electrical service and drain facilities?
2. Is there an unswitched receptacle available for powering
the system?
3. Is there adequate clearance and support to install the
unit and permit access for maintenance? The Conserv
HE-3 RO System may be wall mounted on hinges.
Be certain the unit has clearance to swing out for
maintenance.
4. Does the inlet water supply meet the requirements
listed in the table (on page 2) under Influent Water
Characteristics?
5. Is there a minimum dynamic pressure of 50 psi (3.5 bar,
0.35 MPa) pressure at open flow?
14.4"
(36.5 cm)
39.6"
(100.5 cm)
Provide 3" clearance for
changing cartridges
18.62"
(47.3 cm)
3