TROUBLESHOOTING GUIDE

Problem
Possible Cause
1. Insufficient blended
Cartridge(s) plugged.
water volume during
MR-600F RO Membrane Cartridge plugged.
normal operating
periods.
Insufficient system inlet pressure.
2. Insufficient blended
Refer to Problem 1.
water volume during
System output too low for application.
peak periods.
3. Low quality RO water.
Refer to Problem 1.
MR-600F RO Membrane Cartridge failure.
4. Low water pressure
Restrictive tubing/piping run to equipment.
at water-using
equipment.
5. Objectionable blended
Prefiltration cartridge(s) exhausted.
water odor.
6. Waste water flow too
Drain line restricted.
low or decreases over
time.
Insufficient system inlet pressure.
7. Pressure limit warning
Electrical connector at the pressure transducer not
error.
fully engaged.
RO permeate pressure exceeds 114 psi (0.79 MPa).
RO cartridge bypassing.
32
WATER YOU CAN TRUST
Remedy
Replace cartridge(s).
Replace MR-600F RO Membrane Cartridge.
Check/repair booster pump and inlet line.
Refer to Problem 1.
Verify system output. If output is within specification, increase output if applicable.
Refer to Problem 1.
Replace MR-600F RO Membrane Cartridge.
Increase tubing/piping diameter. Refer to "System Installation" section for recommendations.
Replace prefiltration cartridge(s).
Check/correct any restrictions in drain line tubing. Make sure to allow for an air gap at the drain.
Disconnect reject line at quick-connect fitting and inspect for obstruction or damage. Remove
obstruction. Replace if required.
Check/repair booster pump and inlet line.
Check electrical connector engagement with pressure transducer.
Check for restriction/blockage in permeate line causing abnormally high pressure. Relieve
pressure in permeate line and correct restriction/blockage condition.
Measure RO permeate flow and TDS, then compare to previously recorded values or system
specifications. High permeate flow and/or poor TDS reduction indicates excessive passage of
water around or within the RO cartridge. Remove the RO cartridge and check the integrity of all
three (3) o-ring seals and correct as needed. If seals appear OK, replace the RO cartridge. After
making the repairs, press any key on controller to clear the fault, then recheck RO permeate
flows and TDS, then compare to previously recorded value or system specifications. If the fault
reappears after returning to normal operation, replace controller and/or pressure transducer or
contact Pentair
®