Pentair Everpure Conserv HE-3 Original Instructions Manual page 13

High efficiency reverse osmosis system
Table of Contents

Advertisement

3
Install Everpure SEN
1. Remove the outer shrink wrap and protective caps from
all of the cartridges.
2. Align the lugs on the Everpure SEN
with the slots in the cartridge ports on the twin prefilter
header. Holding the head/bracket and cartridge firmly,
press the cartridge upward into the head fully, and then
turn the cartridge to the right until it stops (Figure 8).
Install the second SEN
Postfilter Cartridge in the same manner.
NOTE: If a second SEN Cartridge is installed, the pre-
installed plug must be removed.
1
2
Figure 8
4
Flush Everpure SEN
Flushing Valve
Figure 9
EVERPURE
CONSERV
HE-3 RO SYSTEM INSTALLATION AND OPERATION GUIDE
®
®
+
and SEN Fine Filter Cartridges
+
Fine Filter Cartridges
+
Fine Filter Cartridge and the SEN
Pump On/Off
Plug Open
Head
(Pre-installed)
SEN Postfilter
(installed after
tank flush)
+
Fine Filter Cartridge
1. Attach 1/2-inch O.D. tubing for a drain line to the
Flushing Valve. The tubing should run to a drain.
2. OPEN the Flushing Valve.
3. The store soft water supply valve should be open. OPEN
the Soft Water Inlet Valve on the Everpure
HE-3 RO System.
4. Flush the prefilters for a minimum of five (5) minutes at
0.5 gpm (1.8 Lpm).
5. CLOSE the Soft Water Inlet Valve.
6. CLOSE the Flushing Valve.
7. Remove the drain tube.
5
Install Everpure MR-600F RO Membrane Cartridge
1. Align the lugs on the Everpure MR-600F RO Membrane
Cartridge with the slots in the head. Holding the head
and cartridge firmly, press the cartridge upward into the
head fully, and then turn the cartridge to the right until it
stops.
NOTE: If a second MR-600F RO Membrane Cartridge is
installed, the pre-installed plug must be removed.
2. Attach a length of 3/8-inch O.D. tubing to the RO tube
that delivers permeate water to the Storage Tank (Figure
10). The open end should run to a drain.
CAUTION: To prevent damage to the pump (P1), the pump
head should be filled with water (primed) before
the unit is turned on.
Soft Water Inlet Valve
RO Waste
to Drain
NOTE: Cartridges not shown.
Figure 10
Conserv
®
®
Pump (P1)
On/ Off
Switch
System
On/Off
Switch
Permeate Port
Attach 3/8" O.D.
Tubing to Drain
13