4. Locate an appropriate point in the soft water plumbing
to tie in a new section of tubing/piping that can be routed
to the RO system. CLOSE the nearest shut-off valve
that is upstream from the tie-in point and relieve the
pressure in the line. Tie in the new tubing/piping section
and connect it to the Soft Water Inlet fitting. See Figure 6
Conserv HE-3 RO System Assembly.
5. Connect the appropriate size and type of tubing/piping
and associated fittings to the Everpure
RO System. Route the line(s) to the equipment being
serviced (i.e., steam, espresso, coffee, etc.). CLOSE the
Hard and Soft Water Inlet Valves, and the Blended Water
Outlet Valve on the RO system. Reapply pressure to
the hard water and soft water distribution plumbing by
slowly OPENING the shut-off valves that were closed in
the previous steps.
6. Connect a 1/4-inch (6.3 mm) O.D. tube to the port located
at the bottom of the processor labeled WASTE. Route
the other end of the tubing to a drain nearby, securing
it properly. Allow an air gap at the drain, following
any applicable local and national codes. See Figure 6
Conserv HE-3 RO System Assembly.
Soft Water
Inlet Valve
Hard Water
Inlet Valve
RO Waste to Drain
From Storage
Tank
Tank Accumulator
Figure 6 Conserv HE-3 RO System Assembly
12
WATER YOU CAN TRUST
Conserv
HE-3
®
®
Blended Water
Outlet Valve
To Storage Tank
Pump
®
ELECTRICAL AND CONNECTIVITY CONNECTIONS
The Everpure
Conserv
HE-3 RO System is pre-wired at the
®
®
factory. Verify that the supply voltage matches the RO system
operating voltage. Also verify that the supply is a GFI, RCD, or
equivalent protected circuit rated at 15 amps minimum. Verify
that the pump motor switch (Figure 8) is in the off position.
Plug in the power cord.
The bottom of the Everpure Conserv HE-3 RO System has two
electrical connections. The permeate Storage Tank sensor
will plug into the white connector. The Storage Tank pump
power cord will plug into the remaining female connection.
WARNING: For proper operation, do not plug Storage Tank
pump into a wall receptacle.
IMPORTANT: Electrical brown-outs below 100 volts will
require the Everpure Conserve HE-3 RO
System must be turned OFF and back ON
(power cycled).
To monitor the Everpure Conserv HE-3 RO System remotely,
an Ethernet cable (type CAT5, not provided with the system)
must be connected between the RO system and the Internet
router.
To have connectivity between the Everpure Conserv HE-3
RO System and the CES-9100TS E-30C Softener, a phone
cord (type 4 pin RJ11, not provided with the system) must be
connected between the RO system and the softener.
Figure 7
PREFILTER AND RO CARTRIDGE INSTALLATION AND
SYSTEM START-UP
Switch and Valve Starting Positions:
• System Power - Off
• Pump (P1) Power - Off
• Soft Water Inlet Valve - Closed
• Hard Water Inlet Valve - Closed
• Blended Water Outlet Valve - Closed
Ethernet Port
Softener Port