System Assembly - Pentair Everpure Conserv HE-3 Original Instructions Manual

High efficiency reverse osmosis system
Table of Contents

Advertisement

SYSTEM ASSEMBLY

WARNING: Mounting surface may require reinforcement to
support the Processor Assembly safely. Hollow
walls, drywall and other non-structural surfaces
are not suitable for mounting unless reinforced.
WARNING: Do not use screws smaller than #12 (5.5 mm) for
mounting the Processor Assembly.
The Everpure
Conserv
HE-3 Processor Cabinet is designed
®
®
to wall mount using either of two (2) methods.
1. If an Everpure
MRS-600HE-II System is being replaced,
®
the mounting brackets can be reused. The new Conserv
HE-3 will not swing open when using these brackets.
2. A mounting kit may be purchased that includes two (2)
hinges and a template with instructions. This mounting
kit allows the Conserv HE-3 to swing open for access to
the back of the cabinet.
1
Wall Mounting Using the Hinged Mounting Kit
The Everpure
Conserv
HE-3 Processor Cabinet can have
®
®
two (2) mounting hinges attached to one side of the cabinet.
The second half of the hinge is separate and will be mounted
to the wall. See Figure 5 for Dimensions. When this half of the
hinge is correctly mounted to the wall, it allows the cabinet to
be lifted and the hinge pieces to connect to each other.
NOTE: When the processor cabinet is hinge-mounted, it
can swing away from the wall to allow servicing.
Determine that the application site will allow the
cabinet to swing in the desired direction.
CAUTION: Be certain that the holes are vertically level.
Any deviation will cause the Conserv HE-3 RO
System Cabinet to swing during servicing.
1. Place the two (2) hinges in position over the mounting
holes with the pegs pointing up.
2. Secure the hinges with appropriate hardware.
EVERPURE
CONSERV
HE-3 RO SYSTEM INSTALLATION AND OPERATION GUIDE
®
®
1-5/8"
1.63
1-5/8"
1.63
Figure 5
2
Tubing Locations
1. Refer to Figure 6 Conserv HE-3 RO System Assembly
for a description of major components and connection
points. These major components and connections will be
referred to in the following steps.
2. Prepare the plumbing to accept the RO system.
NOTE: The blended water tubing/piping and associated
fittings connecting the RO blended water outlet to
the equipment being serviced should be food-grade
material that meets NSF
with a minimum pressure rating of 100 psi (6.9 bar,
0.69 MPa). The blended water may react with metal
piping, creating a corrosive condition in addition
to imparting an objectionable taste. Plastic pipe or
reinforced beverage tubing are generally very good
material choices for RO water distribution piping.
The size of the blended water tubing/piping should
be 1/2-inch (12.7 mm) O.D. minimum. Distances of
25 feet (7.6 m) or greater from the RO system to the
equipment being serviced should be 1/2-inch (12.7
mm) O.D. minimum.
3. Locate an appropriate point in the hard water plumbing
to tie in a new section of tubing/piping that can be routed
to the RO system. CLOSE the nearest shut-off valve
that is upstream from the tie-in point and relieve the
pressure in the line. Tie in the new tubing/piping section
and connect it to the Hard Water Inlet fitting. See Figure
6 Conserv HE-3 RO System Assembly.
52/64"
.82
2-29/64"
2.45
27-21/64"
27.32
25-45/64"
25.70
Standard 51, 61, or similar,
®
11