All manuals and user guides at all-guides.com INSTALLATION Water Pressure 6. Soldering of joints near the drain port must be done prior to connecting the Drain Line Flow Control fitting (DLFC). A minimum of 20 psi (1.4 bar) of water pressure is required for Leave at least 6"...
Page 4
All manuals and user guides at all-guides.com INSTALLATION continued Typical Residential System Plumbing Bath Tub Lavatory Toilet Kitchen Outside Outside Faucet Faucet Hot Water Grounding Soft Water Outlet Strap Hard Water Bypass Drain Line Water Heater Brine Tank Over ow Drain (Optional) Laundry Tubs Pump Meter...
All manuals and user guides at all-guides.com START-UP INSTRUCTIONS/ SYSTEM DISINFECTION FLUSHING & CONDITIONING Disinfection of Water Softeners The water softener should be installed with the inlet, The materials of construction of the modern water softener outlet, and drain connections made in accordance with the will not support bacterial growth, nor will these materials manufacturer’s recommendations, and to meet applicable contaminate a water supply.
All manuals and user guides at all-guides.com TOUCHSCREEN CONTROL FEATURES Assistance: Features of the XTRI Touchscreen Control Displays a name and phone number to call for unit service. • Full-featured easy to use graphical touchscreen interface for programming, servicing, and diagnostics. USB Connect: •...
All manuals and user guides at all-guides.com TOUCHSCREEN SETUP Using the keypad, type the name of the water treatment The XTRI control was designed to be easy to set up and begin professional or company that the homeowner may call for using right out of the box.
Page 8
All manuals and user guides at all-guides.com TOUCHSCREEN SETUP (continued) Settings The Settings screen allows you to change basic control settings including time of regeneration and water hardness. These 5. After pressing , the Home screen (Figure 8) appears. settings improve the operational efficiency of the system and can be adjusted independently from other control settings Next Scheduled without needing to enter Master Settings.
All manuals and user guides at all-guides.com • Master Settings: Displays the Master Settings screen, After entering the correct password and pressing , the main which allows you to fully program the valve. Master Settings screen is displayed. • Brightness/Sound: Displays the Brightness/Sound screen, which allows you to adjust the backlight of the control screen and allows you to mute the alarms of the control.
Page 10
All manuals and user guides at all-guides.com MASTER SETTINGS PROGRAMMING Valve Screen (continued) From the main Master Settings screen (Figure 13) press the valve button to display the Valve screen. The following is a detailed overview of settings available in Master Settings. Please see the MASTER SETTINGS REFERENCE CHART for the complete set of values and ranges available to program while in Master Settings.
Page 11
All manuals and user guides at all-guides.com • regen flow: Contains settings for the type of regenerant The reserve should be set to ensure that the system delivers treated water between the time the system capacity is depleted flow to be used in the valve. Changes to this setting and the actual regeneration time.
Page 12
All manuals and user guides at all-guides.com MASTER SETTINGS PROGRAMMING Settings Review (continued) From the main Master Settings screen (Figure 13) press the settings review button to display the Settings Review screens, which display a read-only summary of all programmed settings in the control.
All manuals and user guides at all-guides.com ADDITIONAL FEATURES From the secondary Master Settings screen (Figure 22) press the remote regen button to display the Remote Regen screen. Press the screen navigation arrow at the top right of the Master Settings screen (Figure 13) to navigate to the secondary Master Settings screen.
All manuals and user guides at all-guides.com REGENERATION are stored in a non-volatile memory and are stored indefinitely with or without power. After a long power outage, the Time Start a regeneration by pressing the Regeneration button of Day button may flash indicating it needs to be reset. Press The Regeneration screen appears (Figure 26).
All manuals and user guides at all-guides.com DIAGNOSTICS NOTE: If a regeneration occurs while in the Diagnostic screen, the unit will return to the main screen. The control records and displays a variety of diagnostic data to assist with troubleshooting performance issues and fine-tuning Parameter Description system efficiency.
All manuals and user guides at all-guides.com If the display is in sleep mode when an error occurs, the screen will turn on for five minutes. The error will beep for one second per minute until the error is cleared. If the error is not cleared after five minutes, the screen will switch to power saving mode and display the Error Alert button as a screen saver.
All manuals and user guides at all-guides.com TROUBLESHOOTING Problem Cause Correction Valve constantly Error in programming has caused Disconnect the motor from the control circuit board (see "WIRING DIAGRAM" on regenerates a regeneration loop condition in the page 43 for location on circuit board). A Motor Stall error will occur, allowing control.
The Fleck 5800/5810/5812 XTRI Connected Valve can be paired with a smartphone or tablet. New users can download and install the Pentair Home App from the App Store or Google Play. WiFi connection must be 4G or less. Sign Up and Log In New users will need to create an account to monitor their water softeners.
Page 19
All manuals and user guides at all-guides.com Sign into the app with your verified email and password. If you have a Pentair Partner Center Account, you should select yes you are a participant. If you will be the main administrator for the Pro account, then select Admin.
Page 20
All manuals and user guides at all-guides.com In the event you are not a Partner Center user, then please After pressing CONTINUE, the app will then take you to the select No and proceed through the log in pages. This will dashboard.
Page 21
All manuals and user guides at all-guides.com 2. Turn the Bluetooth to “ON” and then click the check mark at The screens will now take you through the provisioning process. the bottom right hand corner. 3. A Bluetooth icon will appear in the upper right hand corner of the main screen.
Page 22
All manuals and user guides at all-guides.com 5. A list of available devices will appear. Once the device is 7. Once pairing is complete, if you are using the Pentair Pro found, select that device from the list. App, set up is complete.
All manuals and user guides at all-guides.com MASTER SETTINGS REFERENCE CHART Before entering Master Settings, please contact your local professional water dealer. CAUTION Screen Name Parameters Values Notes Format Language English, French, Changes the language to display screen text and button labels in the control (available with international German, Italian, version of control only).
All manuals and user guides at all-guides.com 5800 CONTROL VALVE PART NUMBERS Item No. Part No. Description 1 ....1 ..580008-004 ... Turbine Meter, Downflow Softener, U.S. Power Supply, #00 Injector, 0.125 GPM BLFC ..580008-005 ... Turbine Meter, Upflow Softener, U.S. Power Supply, #00 Injector, 0.125 GPM BLFC ..
All manuals and user guides at all-guides.com POWERHEAD ASSEMBLY Item No. Part No. Description 1....1 ..43261 ....Cover, Black 2....1 ..43262-00 ....Bezel, Blue ..43262-01 ....Bezel, Black ..43262-02 ....Bezel, Silver 3....1 ..61957 ....Panel Gear Assy, 5800/5810/5812 4....1 ..62126 ....Timer Assy, 5800XTR Touch Scrn w/Logo, International Lang 5....1 ..
All manuals and user guides at all-guides.com 5800 CONTROL VALVE ASSEMBLY BR61500-5800 Rev A Item No. Part No. Description ..60706-10 ....DLFC, QC x 3/4"F, 10 GPM 1 ....1 ..61857-01 ....Valve Body Assy, Downflow/Upflow ..60706-12 ....DLFC, QC x 3/4"F, 12 GPM (Includes Items 9, 10, 11, 12) ..
All manuals and user guides at all-guides.com 5812 CONTROL VALVE ASSEMBLY Item No. Part No. Description 1....1 ..61961 ....Kit, Mounting, 5810/5812 2....1 ..61960-01 ....Kit, Piston, Seal, and Spacer, 5812, Downflow ..61960-02 ....Kit, Piston, Seal, and Spacer, 5812, Upflow ..
All manuals and user guides at all-guides.com WATER CONDITIONER FLOW DIAGRAMS 5800 Upflow 1. Service Position (Treatment) 4. Rapid Rinse Position (Rinse) 2. Brine/Slow Rinse Position (Draw) 5. Brine Tank Refill Position (Refill) 3. Backwash Position 34 • FLECK 5800/5810/5812 XTR I Service Manual...
Page 35
All manuals and user guides at all-guides.com WATER CONDITIONER FLOW DIAGRAMS 5800 Downflow 1. Service Position (Treatment) 4. Rapid Rinse Position (Rinse) 2. Backwash Position 5. Brine Tank Refill Position (Refill) 3. Brine/Slow Rinse Position (Draw) FLECK 5800/5810/5812 XTR I Service Manual • 35...
Page 36
All manuals and user guides at all-guides.com WATER CONDITIONER FLOW DIAGRAMS 5810 Upflow 36 • FLECK 5800/5810/5812 XTRI Service Manual...
Page 37
All manuals and user guides at all-guides.com WATER CONDITIONER FLOW DIAGRAMS 5810 Downflow FLECK 5800/5810/5812 XTRI Service Manual • 37...
Page 38
All manuals and user guides at all-guides.com WATER CONDITIONER FLOW DIAGRAMS 3. BACKWASH POSITION 5812 Upflow 1. SERVICE POSITION 2. BRINE/SLOW RINSE POSITION BRINE LINE INLET 5. BRINE TANK REFILL POSITION BRINE LINE INLET BRINE TANK RESIN TANK 38 • FLECK 5800/5810/5812 XTRI Service Manual...
Page 39
All manuals and user guides at all-guides.com WATER CONDITIONER FLOW DIAGRAMS 3. BRINE/SLOW RINSE POSITION DRAIN 5812 Downflow BRINE CAM BRINE VALVE BRINE LINE INLET AIR CHECK BRINE TANK RESIN TANK 2. BACKWASH POSITION DRAIN BRINE CAM BRINE VALVE BRINE LINE INLET AIR CHECK 5.
All manuals and user guides at all-guides.com 5800 DIMENSIONAL DRAWINGS Measurements inches 12.7 53.8 111.3 2.12 4.38 91.4 3.60 182.9 7.20 26.7 DISTRIBUTOR TUBE OD 1.05 BR61500-5800LNE Rev A 40 • FLECK 5800/5810/5812 XTR I Service Manual...
All manuals and user guides at all-guides.com WIRING DIAGRAM PRODUCTION TEST PORT REMOTE REGEN LOCK REMOTE REGEN START MOTOR / OPTO. ENC. FLOW METER CHLORINE 12VDC GENERATOR + 24VDC COMM PORT AUX2 CMN AUX2 NO AUX2 NC AUX1 CMN AUX1 NO AUX1 NC RESET TOUCHSCREEN...
Refer to the system Installation and Service Manuals for set-up compliance and CSA B483.1 and programming instructions. Contact your local dealer for parts and service. See your owner’ s manual for warranty information. Pentair Residential Filtration, LLC 13845 Bishops Drive Suite 200 Rev. F 7/16/19 Brookfield, Wisconsin 53005 PHONE: (262)-238-4400 FLECK 5800/5810/5812 XTRI Service Manual •...
& lead free compliance for set-up and programming instructions. and CSA B483.1 Contact your local dealer for parts and service. See your owner’ s manual for warranty information. Pentair Residential Filtration, LLC 13845 Bishops Drive Suite 200 Brookfield, Wisconsin 53005 PHONE: (262)-238-4400 Rev.
Installation and Service Manuals for set-up and programming instructions. & lead free compliance Contact your local dealer for parts and service. See your owner’ s manual for warranty information. and CSA B483.1 Pentair Residential Filtration, LLC 13845 Bishops Drive Suite 200 Brookfield, Wisconsin 53005 Rev. B 7/09/19 PHONE: (262)-238-4400 FLECK 5800/5810/5812 XTRI Service Manual •...