USER INTERFACE (UI)

The operator of the Conserv HE-3 RO System can use the
touch screen display to access real-time performance data.
Operating parameters and calibration settings may be
reviewed and changed.
Navigation
Press once to access the item shown.
Button
Individual item usually followed by a
Item Name
value.
The real time value of the individual
Value
item. Also used for calibration values.
The up/down arrows are used to
Setting
change the setting value.
Cancel any changes on the current
screen.
Confirm and save any changes on the
current screen.
Jump back one screen.
Jump to the top level home page.
Previous screen, cycles between
screens within each section shown.
Next screen, cycles between screens
within each section shown.
Sleep Mode
The user interface will enter sleep mode after five (5) minutes
of inactivity. The screen will become blank, but all the
functions continue to operate. To wake the screen from sleep
mode, press anywhere on the screen for two (2) seconds.
12
Place Into Operation
When the cartridges are flushed and the blend is set, the
Everpure
Conserv
HE-3 RO System is ready to begin
®
®
operation.
All of the tubing should be properly connected (Figure 6).
• OPEN the Hard Water Inlet Valve.
• OPEN the Soft Water Inlet Valve.
• CLOSE the Blended Water Outlet Valve.
• Turn ON the Pump Switch.
• Turn ON the System Switch.
Perform the following procedure to start up the HE-3 RO
System using basic settings.
The User Interface will display the top level Home Screen.
EVERPURE
CONSERV
HE-3 RO SYSTEM INSTALLATION AND OPERATION GUIDE
®
®
Conserv
System
Status
Filter Life
Calibrate
Sensors
Lockout
Figure 16
1. Press System Settings and enter the password to access
the Air Purge/Flush menu.
NOTE: Passwords are available through Pentair Everpure
Technical Support at 630.307.3000.
2. Press the Perform Tank Fill button to set the water level
in the tank.
Air Purge/Flush Menu
Perform
Air Purge
Perform
Tank Fill
Figure 17
Tank Fill Cycle
Tank Fill in progress.
Tank Fill %
Figure 18
When the Tank Fill Cycle is complete, the Tank Fill %
window indicates the percent full.
If the Tank Fill % is over 80%, the Conserv HE-3 RO
System is ready for operation.
3. OPEN the Blended Water Outlet Valve.
If the Tank Fill % is under 80%, an Air Purge/Flush Cycle
must be performed.
4. Return to the Air Purge/Flush menu, press Perform Air
Purge and record the Set value. Select Start.
HE-3
®
Reset
System
Settings
Contact
Info
Clear
Date and
Time
Perform
RO Flush