NOTE: The Air Purge is used to push out any air that may
have entered the Storage Tank. Pressure will build
in the Storage Tank until air is forced out of the
Pressure Relief Valve.
Air Purge/Flush Cycle
Set value then press START.
Set
1400
Figure 19
5. Begin the Air Purge by pressing Start. Observe the tank
relief valve. When the Air Purge Cycle is over, if no water
has exited the valve then increase the Set value by 25.
Press Start and run another Air Purge. Continue to
increase the Set value and perform an Air Purge until
water exits the Tank Relief Valve.
6. When the Air Purge is complete, press the Arrow button
at the bottom of the screen. The System Settings menu
should be showing.
System Settings Menu
Date and
Time
Units of
Measure
Figure 20
7. Next, press the Store Settings button to display the Store
Settings menu. Next select Customer Number. The
display will show a screen to enter the customer and
location information for the installation.
Contact Pentair
Everpure
®
the customer ID and location numbers.
Set Customer Number
Customer #
01
1
2
7
8
Figure 21
18
WATER YOU CAN TRUST
Cnt
START
420
Store
Settings
Air Purge/
Flush
Technical Support to obtain
®
Location #
01234
3
4
5
6
9
0
X
®
Remote monitoring must be enabled to allow a Pentair
CES-9100TS E-30C Water Softener to communicate with
the Everpure Conserv HE-3 RO System.
To have connectivity beween the Everpure® Conserv®
HE-3 RO System and the CES-9100TS E-30C Softener,
a phone cord (Type 4 pin RJ11, not provided with the
system) must be connected between the RO system and
the softener.
Figure 22
8. On the Store Settings menu, press the Softener In Use
button to enter a Yes or No setting, Figure 23.
NOTE: Only the Pentair CES-9100TS E-30C Water Softener
may be used with the Conserv HE-3 Controller.
Set Softener In Use
CES-9100TS E-30C
Water Softener In Use
Figure 23
9. Return to the top level home screen.
SYSTEM RECOVERY RATE
The amount of incoming water that becomes RO water
should be 80%. This recovery percentage may be changed
by replacing the flow restrictor in the black waste tubes
located in the RO waste tubing connectors. There is one Flow
Restrictor for each RO head. They are accessed from the top
of the manifold tray.
CAUTION: The system should be run on 80% recovery when
tempered, softened, and under 1,000 ppm TDS
water is available. Any deviation from an 80%
recovery rate will affect the system's production
rate and/or life of the RO membrane. Please
consult Pentair Everpure for a recommendation
of any installation that does not meet this water
specification.