Pentair Everpure Conserv HE-3 Original Instructions Manual page 27

High efficiency reverse osmosis system
Table of Contents

Advertisement

Press the Perform Tank Fill Button to display the Tank Fill
Progress screen. This will show the tank percentage full and
the current action.
Select Perform RO Rinse will pass water over a new RO
cartridge to initialize it.
At the start of an Air Purge, the Storage Tank must be above
80% full (as shown on the Tank Fill Cycle screen) for the Air
Purge to finish properly. If the Storage Tank is below 80% full,
navigate to the System Settings Menu and select Air Purge/
Flush. When the four (4) choices appear, press the Perform
Tank Fill button. A forced manual Storage Tank fill will occur.
When the Storage Tank fill is completed, return to the Air
Purge/Flush Cycle menu and record the Set value. Move back
to the Air Purge/Flush Menu and select Perform Air Purge.
NOTE: The Air Purge is used to push out any air that may
have entered the storage tank. Pressure will build in
the tank until air is forced out of the pressure relief
valve.
Observe the Storage Tank Pressure Relief Valve. When the
Air Purge cycle is over, if no water has exited the valve then
increase the Set value by 25. Press Start and run another
Air Purge. Continue to increase the Set value followed by an
Air Purge until water exits the Storage Tank Pressure Relief
Valve.
During an Automatic Air Purge, the status will be filling. The
Storage Tank level will be increasing.
IMPORTANT: The Storage Tank Air Purge cycle is based on
a setting that was established from the Air
Purge settings screen. If a manual Air Purge
was performed or excess water is leaking
from the Storage Tank Pressure Relief Valve,
the Storage Tank water level setting should be
reset.
EVERPURE
CONSERV
HE-3 RO SYSTEM INSTALLATION AND OPERATION GUIDE
®
®
Tank Fill Cycle
Tank Fill in progress.
0
Tank Fill %
Air Purge/Flush Cycle
RO Rinse in progress.
System Settings Menu
Date and
Store
Time
Settings
Units of
Air Purge/
Measure
Flush
Air Purge/Flush Menu
Perform
Perform
Air Purge
RO Flush
Perform
Perform
RO Rinse
Tank Fill
Air Purge/Flush Cycle
Set value then press START.
Set
Cnt
START
420
1400
27

Advertisement