Press the Tank Level button to display the Tank Level
Calibration screen. Use the "m" and "b" values that are
shown on the Storage Tank sensor packaging.
CAUTION: If the High setting is above the value displayed
in the Run window, (refer to Pump 2 Threshold
Calibration screen) the (P1) pump will not turn off.
If the Low setting is below the value displayed in
the Run window, the (P1) pump will not turn on.
To calibrate the tank level sensor:
1. Press the window for the "m" value.
2. Use the Up and Down arrows to enter the value listed on
the sensor.
3. Press the window for the "b" value.
4. Use the Up and Down arrows to enter the value listed on
the sensor.
5. When finished, press the Check Mark to save the
changes.
NOTE: The Counts window is used by Pentair Everpure
Customer Service as a diagnostic tool.
Press the TDS Sensors button to display the TDS Calibration
screen. Use the calibration setting (C) that is shown on the
sensor packaging.
To change the TDS calibration setting:
1. Press the window for the "C" value of the sensor.
2. Use the Up and Down arrows to enter the value listed.
3. When finished, press the Check Mark to save the
changes.
EVERPURE
CONSERV
HE-3 RO SYSTEM INSTALLATION AND OPERATION GUIDE
®
®
Tank Level Calibration
Tank Level
m
b
67
28
Counts
18
TDS Calibration
C
TDS 1
3.30
TDS 2
3.30
TDS 3
3.30
TDS 4
3.30