Pentair Everpure Conserv HE-3 Original Instructions Manual page 28

High efficiency reverse osmosis system
Table of Contents

Advertisement

Calibrate Sensors Menu Interface
On the top level menu, accessing the Calibrate Sensors Menu
requires a password. Contact Pentair Everpure to acquire the
password.
CAUTION: Incorrect sensor settings will result in improper
operation of the Everpure
System. Sensor calibration has been set at the
factory and should only be changed if a new
sensor has been installed. Use the calibration
data listed on the new sensor.
At the Home Screen, enter the password. The Calibrate
Sensors Menu displays:
Used to enter pressure sensor calibration
Pressure
settings.
Sensors
Used to enter permeate pump (P2) threshold
Pump 2
calibration settings.
Threshold
Used to enter Storage Tank level sensor
Tank
calibration settings. Also used to enter offset
Level
percentages for tank fill and tank empty.
Used to enter calibration settings for the four
TDS
(4) TDS sensors.
Sensors
Used to enter sensor calibration settings for
Flow
flow meters F1 and F2.
Meters
Select Production Test from the System
Production
Settings Menu to access troubleshooting and
Test
sensor information. The tank sensor has a
preset value and will not be shown.
CAUTION: The Storage Tank will be in fill mode as long as
the Production Test screen is displayed. When
this screen has been exited, the Storage Tank
will stop filling.
Press the Pressure Sensors button to display the Pressure
Calibration screen. Use the "c" value that is provided with the
new sensor.
To change the settings:
1. Press the window for the "c" value of the sensor.
2. Use the Up and Down arrows to enter the value listed on
sensor packaging.
3. When finished, press the Check Mark to save the
changes.
Press the Pump 2 Threshold button to display the Threshold
Calibration screen. This screen sets the pressure value for
the permeate pump (P2).
To properly set this value:
After blend is set, unplug tank pump. Allow system to
normalize, then record Run value. Enter Run value +5 into Set
box, confirm input, then re-plug in the pump.
28
WATER YOU CAN TRUST
Conserv
HE-3 RO
®
®
®
Calibrate Sensors Menu
Pressure
Pump 2
Tank
Sensors
Threshold
Level
Production
TDS
Flow
Test
Sensors
Meters
Pressure Calibration
Sensor#
m
c
Sensor 1
-
Sensor 2
-
-
Sensor 3
-
Sensor 4
Sensor 5
-
Pump 2 Threshold Calibration
Set
Run
Low
30
0
After blend is set, unplug tank pump.
Allow system to normalize, then
record Run value. Enter Run value +5
into Set box, confirm input, then
re-plug in pump.