Soft Water Inlet Valve
NOTE: Cartridges not shown.
Figure 12
NOTE: Any air in the Storage Tank will need to be released.
The Air Pressure Relief Valve will open to remove
trapped air.
8. When the Storage Tank is full, CLOSE the Prefilter
Flushing Valve.
9. Allow the Storage Tank to sit for 15 minutes.
10. Drain the Storage Tank by OPENING the Drain Line
Ball Valve and applying power to the Storage Tank. The
Permeate Pump (P2) will turn on.
WARNING: When applying external power to the Storage
Tank Pump, do not run the pump after the
bladder is empty. When the bladder stops
collapsing, it is empty. Failure to follow this
instruction is likely to damage the pump.
11. Remove power to the Storage Tank and CLOSE the Drain
Line Ball Valve.
12. Repeat Steps 6 through 10, two (2) times.
13. Check that power is off to the Everpure
RO System.
14. Remove the tubing from the Prefilter Flush Port and
switch it to service (closed).
EVERPURE
CONSERV
HE-3 RO SYSTEM INSTALLATION AND OPERATION GUIDE
®
®
9
1. Remove the 3/8" to 1/2" Tubing Adapter and the 1/2" O.D.
1/2" O.D.
Tubing
From Tank
to Permeate
Sensor
Adapter
Cable
2. Remove the ball valve from the Storage Tank Drain Line.
CAUTION: A water pressure reducing valve has been
Conserv
HE-3
®
®
3. Connect the tubing with the water pressure reducing
4. Use the Sensor Adapter Cable to connect the electrical
5. Install the Storage Tank cover by removing the fitting at
Connect Tank Tubing
tubing. Connect 3/8" tubing from the Storage Tank to
the connection (RO water out) on the Conserv HE-3 RO
System (Figure 13).
NOTE: Cartridges not shown.
3/8" O.D. Tubing To Tank Inlet
Inlet
Plug Into Storage Tank
Figure 13
included in the parts kit. This valve must be
assembled into the 1/2" O.D. tubing from the
Storage Tank to the permeate inlet. The
directional arrow on the body must point
towards the permeate inlet.
Failure to install the water pressure reducing
valve properly will likely cause damage to the
Conserv HE-3 RO System.
valve from the Storage Tank Outlet (Storage Tank Drain
Line) to the permeate inlet connection on the Conserv
HE-3 RO System (Figure 13). The water pressure
reducing valve has a directional arrow molded into the
body. This arrow must point towards the Conserv HE-3
Cabinet.
port on the bottom of the Storage Tank to the white
connector from the Conserv HE-3 Cabinet.
the top. Position the cover and replace the fitting.