Pentair Everpure Conserv HE-3 Original Instructions Manual page 23

High efficiency reverse osmosis system
Table of Contents

Advertisement

Press the History button to display the first page of the
system's history. Use the Left/Right arrow buttons to move to
pages 2 and 3.
NOTE: Most of these values cannot be reset in the History
menus, with the exception of filter life percentages.
All of the values are real-time unless listed as Max
or Min.
The maximum and minimum inlet TDS values reflect the
highest and lowest TDS readings over the life of the system.
NOTE: Recovery and Rejection percentages will not total
100%. Recovery is the percentage of water that
becomes RO permeate and is sent to the Storage
Tank. Rejection is the percentage of minerals in
the water that do not pass through the RO filter
membrane.
EVERPURE
CONSERV
HE-3 RO SYSTEM INSTALLATION AND OPERATION GUIDE
®
®
History Page 1
Pre-Filter Life
100 %
Post-Filter Life
100 %
RO Membrane Life
100 %
Max Recovery
80 %
Min Recovery
90 %
History Page 2
RO Pump Cycles
1234567
RO Pump Hours
12345
Tank Pump Cycles
1234567
Tank Pump Hours
12345
# of Air Purge
0
# of Flushes
0
History Page 3
Inlet Flow Total
1234.5 gals
Max Inlet TDS
1234.5 gals
Min Inlet TDS
809 ppm
Blend Flow Total
1234.5 gals
Max Blend TDS
0 ppm
Min Blend TDS
0 ppm
23

Advertisement

Table of Contents
loading

Table of Contents