Data Validation

You can use this procedure to configure data validation.
1. Click Configuration | IO-Link Settings.
2. Click the EDIT button on the port you want to configure for data validation.
3. Select Loose or Strict to enable data validation.
 Loose - the slave device's PDI/PDO lengths must be less than or equal to the user-configured
values.
 Strict - the slave device's PDI/PDO lengths must be the same as the user-configured values.
4. Click the GET ATTACHED button or manually enter the PDI and PDO length.