Ip Address Assignment; Assigning An Ip Address Via Io Controller (Dcp) - Leuze electronic MD 748i Connecting And Operating Instructions

Profinet io-link master
Table of Contents

Advertisement

Figure 1: Inserting an MD 248i-12-8K/L4-2R2K into a PROFINET IO System
3.4

IP Address Assignment

Leuze electronic IO-Link Master gateways support three methods for IP address assignment according to
GSDHML Specification V2.31
 DCP - The DAP supports IP address assignment via Discovery and basic Configuration Protocol
(DCP). See 3.4.1 Assigning an IP Address via IO Controller (DCP) for procedures.
 DHCP - The DAP supports the Dynamic Host Configuration Protocol for IP address assignment.
See 3.4.2 Assigning an IP Address via DHCP for procedures.
 LOCAL - The DAP supports a device specific method for IP address assignment. See 3.4.3
Assigning an IP Address Statically (LOCAL) for procedures.
3.4.1

Assigning an IP Address via IO Controller (DCP)

An IO controller can assign an IP address to the Leuze electronic IO-Link Master gateway via DCP. The IO
controller and the Leuze electronic IO-Link Master gateway have to be on the same subnet. The IO-Link
Master default IP address is: 192.168.60.101 and the subnet mask is 255.255.255.0.
1. Double-click the X1 PNIO-IO interface of the IO control to open the
2. On the General tab, click the Properties button, which opens the
window.
Leuze electronic
.
MD 748i / MD 248i
3 Configuring the IO-Link Master with STEP 7
Properties
Ethernet interface Properties
window.