Configuration with Web Browser
Unit ID:
Each VideoJet 1000 should be assigned a unique identifier which
can be additionally used to identify the unit.
Website language:
Here you select the desired language of the HTML pages.
Password level:
The access to a VideoJet 1000 is generally protected with a pass-
word in order to prevent unauthorised use of the device. The trans-
mitters operate with three authorisation levels: Live, Service and
User.
In the authorisation level Service, you can change all the configu-
ration settings after entering the corresponding password.
With the authorisation level User you can operate but not configure
the device. You can have a live picture or the configuration settings
displayed, but you cannot change them.
With Live you can display a live video but neither change the con-
figuration nor for example control a camera.
Password:
You can define and change passwords for access to the device
when you are working with the authorisation level Service or if the
device is not protected with a password. You can change only one
of the three passwords at a time. In order to change the password
of another level, you have to call up this configuration page again.
Password confirm:
Enter the new password again to rule out the risk of typing errors.
System date and System time:
If a number of VideoJet 1000 units are combined in a system, it is
important that the internal clocks of the separate units are all syn-
chronized. Only if all units operate with the same time it is possible,
for example, to correctly identify and evaluate events which have
occurred simultaneously.
Enter the current date and time. As the system time is controlled by
the internal calendar clock, the day of the week does not have to be
entered. It is added automatically.