4.1.2 Voltage changes, voltage fluctuations on AC mains

Result:
Date of testing
Test procedure
Ambient
condition
According to the characteristics of the sample, as specified by clause 5 of the basic standard,
following limits apply:
 the value of d(t) during a voltage change shall not exceed 3.3% for more than 500ms;
 the relative steady-state voltage change, d
 the maximum relative voltage change d
The measurement was carried in accordance with Annex B of the basic standard. Following
are the measurement results obtained via an automatic testing system.
Table 6: Voltage fluctuations measurement results for TS-315A
Limits
Result
Table 7: Voltage fluctuations measurement results for TS-315E
Limits
Result(I)
Result(II)
Result(III)
17706754 001
03.11.2015
:
:
EN 61000-3-3:2013
:
Tempreture:20°C, relative humidity: 50%
d
d
c
max
3.3%
7%
0.537%
6.590%
d
d
c
max
3.3%
7%
0.157%
3.748%
0.154%
4.100%
0.152%
3.769%
, shall not exceed 3.3%;
c
, shall not exceed 7%
max
d(t)
P
st
3.3%/500ms
1.0
140ms
-
d(t)
P
st
3.3%/500ms
1.0
10ms
-
10ms
-
10ms
-
Seite 12 von 18
Page 12 of 18
Passed
P
lt
0.65
-
P
lt
0.65
-
-
-