Test Report No.: No.: 17706687 001
Part II of II
Requirement  Test
Clause
22.6
Capacitor between contacts of thermal cut-outs
22.7
Components for basic radio and interference
suppression
22.8
Inductors for basic radio and interference
suppression inserted in the earthing circuit
Testing of inductors ................................................. :
22.9
Appliance couplers
23
SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS
23.1
Type of connection
Prevention of replacebility of power supply cord
type M with type X
Accessibility of appliance inlet
23.2
Non detachable flexible cables and cords
Type
Green/yellow insulation of earthing conductor
Supply cords of tools intended to be connected to
a water supply shall not be lighter than ordinary
polychloroprene-sheathed flexible cord (code
designation H05 RN-F).
23.3
Plug according to IEC60083 and EN60309-1/-2
23.4
Cross-sectional area of flexible cables and cords
23.5
Cord anchorage
Strain relief for type X flexible cables
Cord anchorage of power supply cords of class II
tools
Strain on earthing conductor of class I power cord
Cord anchorage in tools others than class II
Cord anchorage of type X cords
Replacibility of cord anchorage of type X cords
Screws operated when replacing the power supply
Page 35 of 63
EN 61029-1:2009+A11
Result - Remark
Plug fixed on the machine
frame functioned as an
appliance inlet.
H07RN-F
Provided
The plug is approved according
to VDE 0620-1 for single phase
models and EN60309-1/-2 for
other models.
1.5mm
No cord anchorage for external
cable provided on the machine.
2
Verdict
P
N/A
N/A
N/A
N/A
P
P
N/A
P
P
P
P
N/A
P
P
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A