Produkte
Products
Prüfbericht - Nr.:
:
Test Report No.
4 Test Results E M I S S I O N
4.1 Emission in the Frequency Range up to 30 MHz
4.1.1 Harmonics on AC Mains
Result:
Date of testing
Test procedure
Test duration
Harmonic order
Frequency range
Ambient
condition
Following are the measurement results, which were obtained via an automatic measurement
system.
The only electrical part that may generate RF noise incorporated in the sample is induction
motor. Therefore the harmonics test was performed on the motor.
17706754 001
03.11.2015
:
:
EN 61000-3-2:2014
2.5min
:
th
2 – 40
:
0 – 2kHz
:
:
Tempreture:20°C, relative humidity: 50%
Seite 7 von 18
Page 7 of 18
Passed