Test Report No.: No.: 17706687 001
Part II of II
Requirement  Test
Clause
To determine the uncertainty K of the declared
value according to EN 12096, the following
formula shall be used that takes the standard
deviation into account:
K= 1,65 s
higher
With
s
= standard deviation (considered equal to O
R
n = 3 (number of operators)
a
= average vibration total value of each
hvj
operator (= result for each operator)
a
= average vibration total value of all
h
measurements (= test result)
The vibration value(s) a
follows:
13.3.8
Measurement report
The report shall, as a minimum, include the
following information:
a) reference to this standard including any
relevant Part 2;
b) specification of the machine tested (i.e.
manufacturer, type and serial number of the
machin etc.);
c) attachment or accessories;
d) operating and testing conditions (voltage, feed
force, speed setting, duration and number of test
runs, etc.);
e) measuring institution (e.g. laboratory,
manufacturer);
f) date of measurement and name of the person
responsible for the test;
g) instrumentation (transducer mass, filters,
Page 26 of 63
EN 61029-1:2009+A11
or K= 1,5 m/s2, whatever is
R
shall be declared as
h
Result - Remark
)
R
Verdict