Assembly instructions
1.7
Existing residual risks (residual risk assessment)
Residual risk
Life cycle: Assembly
Manual filling:
lubricant discharge from the pressure
regulating valve of the lubricant reservoir
in case of overfilling
Risk of slipping due to contamination of
floor by spilled or leaked lubricant
Tearing/damage to supply, compressed
air, and lubricant lines when installed on
moving machine components.
Life cycle: Commissioning/operation
Lubricant spraying out due to faulty instal-
lation of fittings/screw unions on lubricant
lines
Risk of slipping due to contamination of
floor by spilled or leaked lubricant
Remedy
• Perform filling of the lubricant reservoir carefully and stop once the "MAX fill level" (sight glass on
lubricant reservoir) or electrical max. signal is reached.
• Proceed carefully when filling the lubricant reservoir using a filler coupling.
• Promptly apply suitable binding agents and remove the leaked or spilled lubricant
• Follow statutory and company regulations for the handling of lubricants
• If possible, do not install on moving machine parts; If this cannot be avoided, use flexible supply,
compressed air, and lubricant lines.
• Tighten all fittings/screw unions with the appropriate torques (where specified). Use fittings/screw
unions and lubricant lines suitable for the indicated operating pressures. Check all fittings/screw unions
and lubricant lines for correct connection and damage before commissioning
• Proceed carefully when filling the lubricant reservoir using a filler coupling.
• Promptly apply suitable binding agents and remove the leaked or spilled lubricant
• Follow statutory and company regulations for the handling of lubricants