5)
Starting playback of a CUE or restarting a stopped CUE
5.1) When a CUE is being played back or playback is finished (the STOP/REV button is unlit)
* This function is disabled when the NEXT CUE's time memory is in manual mode and playback is
controlled by the manual fader.
* This function is disabled during REV status.
Press the GO button to play back the NEXT CUE.
When you press the GO button, the NEXT CUE number is displayed in the ACTUAL indicator, the
STAND BY CUE number is displayed in the NEXT indicator and the CUE number following the STAND
BY CUE is displayed in the STAND BY indicator.
The LED on the GO button is on during CUE playback. When playback of all CUEs is over, the LED in
the GO button goes out automatically
5.2) When the CUE stops playback (the STOP/REV button is flashing)
Press the GO button to restart playback of the stopped CUE.
6)
Stopping CUE playback
Press the STOP/REV button while the GO button is lit, to stop all the CUEs being played back.
The LED in the STOP/REV button flashes.
7)
Reversing the ACTUAL CUE to the preceding one
* The time to reverse the CUE can be set on the DEFAULT screen.
7.1) When the CUE stops playback (the STOP/REV button is flashing)
* The reverse function is disabled when several CUEs other than the ACTUAL CUE are being played
back, to prevent errors in operation during actual performance.
Press the STOP/REV button to reverse the ACTUAL CUE to the preceding CUE in CLEAN UP mode
playback. At this time, manual operation of CUEs is automatically canceled.
7.2) When playback of all the CUEs is finished (the LED of the GO and STOP/REV button are unlit)
* The nested reverse function is disabled, to prevent errors in operation during actual performance.
Press the STOP/REV button to reverse the ACTUAL CUE to the preceding CUE with playback in
CLEAN UP mode.
During reverse operation, the CUE preceding the ACTUAL CUE is displayed in the ACTUAL indicator,
and the CUE after the one that was previously the ACTUAL CUE is displayed in the STAND BY
indicator.
The STOP/REV button is on during reverse operation. On completion of reverse operation, the LED in
the STOP/REV button goes out automatically.