DIMMER DATA Screen
14) Setting a Fix level for dimmer(s)
> Dimmer name(s) = Select Fix level by ↑ or ↓
Example)
> DIM 2S3 = Fix@90 ↵ OK? ↵
15) Resetting a Fix level for dimmer(s)
> Dimmer name(s) = Select Fix level by ↑ or ↓
Example)
> DIM 2S3 = Fix@ RESET OK? ↵
16) Assigning a BackUp Dimmer to dimmer(s)
* When a BackUP Dimmer is assigned, the BackUp MODE is disabled.
To
enable the BackUP MODE, another operation needs to be performed.
Fo
r information on how to operate the BackUP MODE, refer to Item 18.
> Dimmer name(s) = Select BackUp DIM by ↑ or ↓
F3 (DIM) Burn-out bulb backup load name ↵ ↵
Example)
> DIM 2S3 = BackDM DIM DMX2-512 ↵ OK? ↵
17) Resetting the assignment of a BackUp Dimmer to dimmer(s)
> Dimmer name(s) = Select BackUp DIM by ↑ or ↓
Example)
> DIM 2S3 = BackDM RESET OK? ↵
18) Setting a BackUp MODE for dimmer(s)
* This setting must be made after setting a BackUP Dimmer.
> Dimmer name(s) = Select BackUP MODE by ↑ or ↓
Example)
> DIM 2S3 = BackMD1 ↵ OK? ↵
19) Resetting BackUp MODE for dimmer(s)
> Dimmer name(s) = Select BackUp MODE by ↑ or ↓
Example)
> DIM 2S3 = BackMD RESET OK? ↵
Set 2S3 to Fix level 90%.
Reset the Fix level for 2S3.
Assign Burn-out bulb backup load DMX2-512 to 2S3.
Reset the assignment of a burn-out bulb backup load to 2S3.
Set the BackUP MODE enabled for 2S3.
Reset the BackUp MODE for 2S3.
Level ↵ ↵
RESET ↵
RESET ↵
1 ↵ ↵
RESET ↵
22-4